Global Tab
Start > All Programs > Summit > Summit Client Utility > Global tab
The parameters on this panel can only be changed when an Admin is logged in with a password. The current values for the
parameters can be viewed by the general user without requiring a password.
Note: Tap the Commit button to save changes. If the panel is exited before tapping the Commit button, changes are not
saved!
Factory Default Settings
Roam Trigger -65 dBm
Roam Delta 5 dBm
Roam Period
BG: 10 sec.
A: 5 sec.
BG Channel Set Full
DFS Channels Off
DFS Scan Time 120 ms.
Ad Hoc Channel 1
Aggressive Scan On
CCX
BG: Off
A: Optimized
WMM
On On Off
Auth Server Type 1
TTLS Inner Method Auto-EAP
PMK Caching Standard
WAPI Off (dimmed)
TX Diversity
BG: On
A: Main Only
RX Diversity
BG: On-Start on Main
A: Main Only
Frag Threshold 2346
RTS Threshold 2347
LED Off
Tray Icon On
Hide Passwords On
Admin Password SUMMIT (or blank)
Auth Timeout 8 seconds
Certs Path C:\Program Files\Summit\certs