36 Installation Instructions MB-Secure 1000/2000/3000/4000/5000/6000
6 Specifications
Rated operating voltage 12 V DC
Operating voltage range 10.5 V to 15 V DC
Detector group voltage (terminal works as input) 8 V DC
Current consumption at rated voltage
- disarmed group connections open 200 mA
- Ethernet operation (additional) 30 mA
- per group connection (with 12.1 kΩ closed) 1 mA
- relay 45 mA
Environmental class according to VdS II
Environmental class according to EN 50131-1 Class II
Operating temperature range - 5 C to +45 C
Storage temperature range -25 C to +70 C
Relative humidity max. 93% non-condensing
Optional control panel housing
Dimensions W x H x D in mm
- ZG 20 460 x 382 x 85
- ZG 2 350 x 300 x 152
- ZG 3.1 500 x 300 x 210
- ZG 4 580 x 640 x 300
Weight (without options)
- ZG20 around 5 kg
- ZG2 around 8 kg
- ZG3.1 around 13 kg
- ZG4 (without 19” front panels) around 28 kg
Color
- Housing traffic white (similar to RAL 9016)
- Front light gray (similar to RAL 7035)
Protection class based on EN 60529 IP30
Approvals
- VdS Approval no: G114025 Class C
- EN Conformity: according EN 50131-3:2010-02 Grade 3
- SES Conformity: SES-EMA-RL-T2:2010-08