EasyManua.ls Logo

Honeywell MM14CCS - Troubleshooting Guide

Honeywell MM14CCS
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
TROUBLESHOOTING GUIDE
The following troubleshooting guide addresses the most common problems. If problems
persist, call customer service. Unplug and disconnect the appliance from the power
source before attempting to troubleshoot.
• Reinstall exhaust hose properly
(Refer page 9, Installation)
• Reduce temperature setting on
control panel.
• Remove blockage.
• Make sure the windows and door
are closed.
• Connect exhaust hose as per
instructions on page 9.
Make sure the exhaust hose is
properly connected.
Lower the set temperature.
Runs but no cooling
Runs a short while
only
Problem Possible Cause
Solution
The air conditioning
unit does not start
• Drain the water through the drain
plug (Refer page 14, Water
Condensation Draingage).
• Remove and reconnect the power
cord.
• Reset the safety GFI plug, if
problem persists contact our
customer support.
Check for power.
• Change remote control batteries.
Excess water condensation inside
the tank.
Air outlet or intake is blocked.
Temperature setting is too high.
Clean the air filter
The exhaust hose is detached.
The air filter is dirty.
A door or window is open.
There are tight bends in the air
exhaust hose.
Air outlet is blocked.
The thermostat temperature setting
is too close to room temperature.
plugged in.
The safety GFI plug has tripped.
to be replaced
The power cord is not properly
No electricity.
Batteries in the remote control need
Will not run and
water full indicator
light is ON

Other manuals for Honeywell MM14CCS

Related product manuals