EasyManua.ls Logo

Honeywell Notifier AFP-3030 - Page 5

Honeywell Notifier AFP-3030
22 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DOC-02-159:rev C - Page 5 of 8
DNR: InnovairFlex low-flow non-relay duct-detector housing (order FSP-
851 separately). See DOC-02-098.
DNRW: Same as above with NEMA-4 rating, watertight. See DOC-02-
098.
B501AUS:4” (10.16 cm) universal detector base. See DOC-02-030.
B521IEFT-IV:4” (10.16 cm) universal detector base with in-built short-
circuit isolator. See DOC-02-030.
AAM:Alarm acknowledgement module. Models available in vertical and
horizontal orientation and with (or without) remote indicator; AAM-VL,
AAM-V, AAM-HL. Alarm Acknowledgement Modules. See DOC-02-086.
NFX-BS: CLIP Sounder base, Temporal 3 or Continuous tone. See
DOC-02-144.
NFX-BF:CLIP Beacon base. See DOC-02-144.
NFX-BSF:CLIP Sounder beacon base, Temporal 3 or Continuous tone.
See DOC-02-144.
NFX-WS: CLIP Wall Sounder Temporal 3 or Continuous tone. See
DOC-02-145.
NFX-WF:CLIP Wall Beacon. See DOC-02-145.
NFX-WSF:CLIP Wall Sounder beacon, Temporal 3 or Continuous tone.
See DOC-02-145.
NOTE: NFX addressable AV devices are available in a range of colours.
Colour variants are included as part of the models listed above. For
example red wall sounder is NFX-WS-R. Versions of NFX series
addressable AV are available with in-built short circuit isolator. These are
designated in the model NFXI. for example red wall sounder with isolator
is NFXI-WS-R.
FMM-1:FlashScan monitor module. See DOC-02-040.
FDM-1: FlashScan dual monitor module. See DOC-02-040.
FZM-1:FlashScan conventional zone module. See DOC-02-040.
FMM-101:FlashScan miniature monitor module. See DOC-02-040.
FMM-4-20:FlashScan 4-20 mA protocol monitor module. See DOC-
02-170.
FCM-1:FlashScan control module. See DOC-02-038.
FRM-1:FlashScan relay module. See DOC-02-038.
FDMR-1:FlashScan dual monitor/dual relay module. See DOC-02-033.
NFX-MCP-GLASS: FlashScan manual call point, addressable. See
DOC-02-088.
ISO-X:Isolator module. See DOC-02-042.
WCP-5A:CLIP outdoor manual call point. See DOC-02-088.
XP6-C: FlashScan six-way monitored control module. See DOC-02-
044.
XP6-MA: FlashScan six-zone interface module; connects intelligent
alarm system to two-wire conventional detection zone. See DOC-02-
043.
XP6-R:FlashScan six-relay (Form-C) control module. See DOC-02-045.
XP10-M: FlashScan ten-input monitor module. See DOC-02-046.
IMX-IE: Translator module for use with intrinsically safe devices. See
DOC-02-129
Y-2221:Single channel galvanic isolator for use with IMX-IE. See DOC-
02-129.
SLC-IM:SLC integration module, for VESDAnet detectors or modbus
devices. See DOC-02-174
Enclosures, Chassis and Dress Plates
CABSeriesEnclosures: AFP-3030 mounts in a standard CAB Series
enclosure (available in two sizes, CAB650 and CAB900). The CAB series
encosures are available with a solid and window outer door. A trim ring
option is available for semi-flush mounting.
U Series Enclosures: AFP-3030 mounts in a “U” Series enclosure
(available in three sizes, 18U, 28U and 40U). The “U” Series cabinets are
available with a solid and window outer door. Custom trim ring options
are available for semi-flush mounting.
BMP-1: Blank module for unused module positions.
CHS-3L:Low-profile Chassis. Mounts up to three modules in any CAB
series row.
CHS-4L: Low-profile Chassis. Mounts up to four modules in any U
series row.
CHS-4:Chassis used with the XP6 and XP10 Multi-Modules.
Mounts up to four modules in any CAB series row.
CHS-6: Chassis used with the XP6 and XP10 Multi-Modules.
Mounts up to six modules in any U series row.
CAB650/BB: Enclosure for batteries. The CAB650/BB is used to mount
up to two 40 AH batteries if needed. 250mm high x 450mm wide x
190mm deep. Depth includes door.
18U/BB: Enclosure for batteries and additional equipment. The 18U/BB
is used to mount up to six 40AH batteries (three sets) if needed. 300mm
high x 450mm wide x 190mm deep. Depth includes door.
Other Options
IFS-2008:Agent releasing module for extinguishing agent releasing CIE
in accordance with AS4214.1:2002, AS & ISO14520.1:2009. See DOC-
02-020.
IFS-993:Strobe/sounder interface. See DOC-02-173.
NOTE: For other options including compatibility with retrofit equipment,
refer to the SLC manual, and the AFP-3030 manual.