NFW-50X Manual — P/N LS10129-001NF-E:C 7/25/2018 133
Appendix B: Default Programming
The following table provides a list of the programming options and their factory default settings.
Program Option Factory Default Program Option Factory Default
Detector Programming Not Installed Waterflow Silenceable No
Detector Type Smoke-Photo Relay 1 Alarm
Detector Verification Off Relay 2 Trouble (fixed)
Detector Walktest Yes Relay 3 Supervisory
Detector PAS No Communicator Installed Yes
Detector Presignal No POTS, Ethernet, Cellular Enabled No
Detector Zone Assign. 000 only Ethernet, Cellular Location ID 0000
Detector Adj/Noun none Ethernet, Cellular CS ID 0000
Module Programming Not Installed POTS, Ethernet, Cellular Account Code 000000
Module Type Monitor POTS Enabled No
Module Walktest Yes POTS Type Touchtone
Module Presignal No POTS Supervised No
Module Zone Assign. 000 only Gains Dialing Normal
Module Adj/Noun none Gains Reporting Normal
Module Control Module Delay No IP Settings- DHCP Enabled
Zone Type Alarm Zone Trouble Report Limit 0
Zone 000 Enable Enabled Report Style Point
Zone 001 Enable Enabled AC Loss Delay 2
Zone 002 Enable Enabled Primary Account Code 000000
Zone 003 Enable Enabled Secondary Account Code 000000
.........................through.......... ..................... Test Time 0100
Zone 045 Enable Enabled Primary Phone Number
Special Purpose Zones 046-049 Off Secondary Phone Number
Loop Class Class B Primary Comm Format Ademco Contact ID
Loop Protocol LITESPEED Secondary Comm Format Ademco Contact ID
Trouble Reminder 24 Hr ANN-Primary Enabled No
Banner ANN-Primary Modules Addr. 1 - 8 None
Time Format 12 Hr ANN-Secondary Enabled No
Hours Setting 12 ANN-Secondary Modules Addr. 1 - 8 None
Minutes Setting 00 ANN-S/PG Port Serial
Second Settings 00 ANN-S/PG Baud 9600
AM-PM Setting AM ANN-S/PG Data Bits 7
Month Setting 01 ANN-S/PG Parity Even
Day Setting 01 ANN-S/PG Stop Bits 1
Year Setting 00 ANN-S/PG Offline Timer 60
Daylight Savings Enabled ANN-S/PG Printer Supervision No
Month Start Daylight Savings April ANN-80/100 Piezo Enabled Yes
Week Start Daylight Savings Week 2 ANN-80/100 Lock Enabled Yes
Month End Daylight Savings November ANN-80/100 Acknowledge Button Enabled Yes
Week End Daylight Savings Week 1 ANN-80/100 Silence Button Enabled Yes
Alarm Verification Off ANN-80/100 Reset Button Enabled Yes
PAS Timer 0 ANN-80/100 Drill Button Enabled Yes
Presignal Timer 0 ANN-I/O Point/Zone Zone
Waterflow Retard Timer 0 ANN-I/O Range 00-29
Control Module Delay Timer 0 ANN-I/O Active LEDs Only
NAC 1 & 2 Enable Enabled ANN-RLY Relay 1 Zone 1
NAC 1 & 2 Silenceable Yes ................through....................... ............
NAC 1 & 2 Type Strobe Sync ANN-RLY Relay 10 Zone 10
NAC 1 & 2 Sync Type System Sensor ANN-LED Point/Zone Zone
NAC 1 & 2 Autosilence 0 ANN-LED Alarms/ATS (Alarm, Trbl, Supv) ATS
NAC 1 & 2 Coding Steady ANN-LED Range 0 - 9
NAC 1 & 2 Zones Zone 000 only F1 - F4 function keys Disabled
NAC 1 & 2 Silence Inhibit No Master Password 00000000
Charger Enabled Yes Maintenance Password 11111111
4XTM Supervision No Upload/Download Password 22222222
Remote Sync Enabled Yes
Aux Power Class A No
Aux Power Resettable No
Canadian Option Enabled No