To temporarily ignore the schedule, press or until the desired temperature is displayed. The word Temporary will appear on the
screen and the period display will flash to indicate that the current period has been overridden. The new temperature will be
used until the next period begins.
NOTE: Pressing or once will display the setpoint temperature. To change the setpoint temperature, press either button more
than once.
Press the Run button if you wish to cancel the temporary setting before the beginning of the next period.
PERMANENT OVERRIDE OF SCHEDULE
To permanently ignore the schedule, press or until the desired temperature is displayed. Then, press the Hold button to
maintain the new temperature indefinitely. The word Hold will appear on the screen.
Press the Run button if you wish to cancel the override and resume the schedule. The word Hold will disappear and the
thermostat will be set to the temperature programmed for the current period.
ADAPTIVE INTELLIGENT RECOVERY (AIR)
Adaptive Intelligent Recovery™ allows the thermostat to “learn” how long your furnace or air conditioner takes to reach the set
temperature. Simply program the desired times and desired temperatures into the schedule. The thermostat will determine
when to activate heating or cooling so that the desired temperature is attained at the desired time.
Example: If you set the Wake time to 6 a.m. and the temperature to 70 °F (21 °C), the heat will come on before the set time, so
the temperature is 70 °F (21 °C) by the time you wake at 6 a.m.
BUILT-IN COMPRESSOR PROTECTION
Your thermostat has a feature that helps prevent damage to the compressor of your air conditioning or heat pump system.
Because damage can occur if the compressor is restarted too soon after shutdown, this feature forces the compressor to wait 5
minutes before restarting. During the wait time, the message Cool On or Heat On flashes on the screen. When the safe wait
time has elapsed, the message stops flashing and the compressor turns on.
BATTERY REPLACEMENT
NOTE: Batteries are optional (serving as backup power) only if your thermostat is connected to 24 VAC.
CAUTION: Set the System switch to Off before removing the batteries. Otherwise, the heating/cooling system could remain
activated even when batteries are removed.
Install two fresh AAA batteries when Lo Batt (low batteries) flashes on the screen. The message appears for 60 days before the
batteries are depleted.
Replace batteries once a year, or when you will be away for more than a month.