Loading...
24 Applicator Interface Kit Installation Guide
Display Messages
These messages appear in the printer display under certain conditions when a
PRINTFEED command is run.
EAPPERR3
Message: Applicator Error 3
Cause: AppErr3 in signal detected.
Result: Activates event in System Health Monitor (SHM).
Error number: 1342
ERTWINEXT
Message: RTW External Error
Cause: RTWExternal in signal detected.
Result: Activates event in System Health Monitor (SHM).
Error number: 1343
ENODATAREADY
Message: Dataready not enabled
Cause: Application sent a PRINTFEED in Fingerprint when the
applicator port is enabled, the style is set to I-Style or Z-Style,
and the dataready signal is not enabled.
Result: Terminates the printfeed command without printing a label.
Error number: 1344
Message:
APPLICATOR PORT: Wait for signal
Cause: Running a PRINTFEED command blocks execution until a
startprint signal is received. The message appears when
execution has been blocked for a few seconds.
Message: APPLICATOR PORT: Wait for reprint
Cause: Running a PRINTFEED -1,1 command blocks execution until
a reprint signal is received. The message appears when
execution has been blocked for a few seconds.