Applicator Interface Kit Installation Guide 23
Error Messages
ERRNOAPP
Message: Operation not allowed. Applicator Port disabled.
Cause: Application send an applicator port command to the printer
and the applicator port is disabled.
Error number: 88
ERRAPP
Message: Operation not allowed. Applicator Port enabled.
Cause: Application sent the Fingerprint command PORTOUT(PORT)
ON|OFF on a port used by the applicator port when the
applicator is enabled.
Error number: 89
ERRINPUTON
Message: Operation not allowed in Direct Protocol
Cause: Running the PORTOUT.DATAREADY ON|OFF or
PORTIN.<SIGNAL>GOSUB XXX commands when the printer
is set to using Direct Protocol.
Error number: 90
EAPPERR1
Message: Applicator Error 1
Cause: AppErr1 in signal detected.
Result: Activates event in System Health Monitor (SHM).
Error number: 1340
EAPPERR2
Message: Applicator Error 2
Cause: AppErr2 in signal detected.
Result: Activates event in System Health Monitor (SHM).
Error number: 1341