Installation Guide
69-2200—0
69-2200—0
The DS/BK terminal is used with a variable-speed fan.
Connect to the DS, BK, or ODD terminal on the furnace
equipment. When only one zone calls for heat, cool, or
fan, the DS/BK terminal operates the fan at low speed
to reduce airflow.
7
Connect transformer as shown.
Connect equipment as shown.
6
WIRING
M28236A
EQUIPMENT
R
C
E/Aux
Y
G
O
B
DS/BK
L
AIR
HANDLER
FAN RELAY
AUX/EM HEAT
HEAT PUMP
G
Y
24 VOLT TRANS.
C R
Y
E
C R
REVERSING
VALVE
M27339
R
C
E/Aux
Y
G
O
B
DS/BK
L
AIR
HANDLER
FAN RELAY
AUX HEAT
HEAT PUMP
G
Y
24 VOLT TRANS.
C R
Y
E
C R
REVERSING
VALVE
ZONE 2 THERMOSTAT
ARD OR ZD DAMPER
SPRING-OPEN
POWER-CLOSED
PURGE OVERRIDE
EQUIPMENT
M4 OPEN
M6 CLOSED
M1 COMMON
M1
M4
M6
R
C
E/AUX
Y
G
O
L
THERMOSTAT
R
C
E
AUX
Y
G
O/B
L
RRD OR MARD DAMPER
POWER-OPEN
POWER-CLOSED
M1
M4
M6
R
C
E/AUX
Y
G
O
L
THERMOSTAT
ZONE 1
DAMPER
ZONE 2
DAMPER
DEDICATED
TRANSFORMER
L1
(HOT)
L2
R
C
C7735A1000
DATS
DATS
R
C
HEAT
COOL
FAN
PURGE
ZONE 1
ZONE 2
EM HEAT
EMERGENCY HEAT
POWER
SENSOR
The following diagram is an overall view of wiring for a heat pump system as depicted in steps 3–7.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell TrueZONE HZ221 and is the answer not in the manual?

Honeywell TrueZONE HZ221 Specifications

General IconGeneral
Transformer40 VA
Input Voltage24 VAC
CompatibilityConventional and Heat Pump systems
Operating Temperature32°F to 150°F (0°C to 66°C)
Wire Gauge18 to 22 AWG
Humidity Range5% to 90% RH, non-condensing

Related product manuals