2.9.2 Temperatures
CAUTION!
Protect the device from direct sunlight.
Temperature range Process [°C] Ambient [°C] Process [°F] Ambient [°F]
min. max. min. max. min. max. min. max.
PTFE & PFA
Separate flow sensor -40 180 -40 65 -40 356 -40 149
Compact with TWM 9000 -40 140 -40 65 -40 284 -40 149
Compact with TWM 1000 -40 120 -40 65 -40 248 -40 149
ETFE
Separate flow sensor -40 120 -40 65 -40 248 -40 149
Compact with TWM 9000 -40 120 -40 65 -40 248 -40 149
Compact with TWM 1000 -40 120 -40 65 -40 248 -40 149
Hard rubber
Separate flow sensor
1
-5 80 -40 65 23 176 -40 149
Compact with TWM 9000
1
-5 80 -40 65 23 176 -40 149
Compact with TWM 1000
1
-5 80 -40 65 23 176 -40 149
PU
Separate flow sensor -5 65 -40 65 23 149 -40 149
Compact with TWM 9000 -5 65 -40 65 23 149 -40 149
Compact with TWM 1000 -5 65 -40 65 23 149 -40 149
1 Hard rubber liner is available for Ex-versions only.
INFORMATION!
Ambient temperatures below -25
°
C / -13
°
F may affect the readability of the display