VAM (VISTA Automation Module) - Installation & Setup Guide
Introduction
VISTA Automation Module (herein referred to as “VAM”) combines home automation and home security and is intended
for use with compatible VISTA
®
series control panels. VAM includes a built-in web server, Wi-Fi
®
capability, and Z-Wave
®
technology allowing VISTA installations to support Z-Wave devices.
The VISTA Automation Module also supports Remote Services for controlling Z-Wave devices and Scenes remotely from
an associated Total Connect™ account.
VAM is controlled using a web browser on a Wi-Fi enabled smart device such as a Tablet PC, laptop, Smartphone, etc.
DISPLAY NOTE: For optimum viewing of the screens and menus, the tablet’s font size setting may need to be adjusted.
Make
W
iring
Connections
Connect VAM to the control panel’s keypad data (ECP)
terminals using a standard 4-wire keypad connector harness.
vam-003-V1
TO
CONTROL PANEL
ECP TERMINALS
YELLOW
RED
BLACK
GREEN
CONTROL PANEL
PC BOARD
VAM
REFER TO THE CONTROL PANEL’S INSTRUCTIONS
FOR MAXIMUM WIRE LENGTHS.
4-WIRE CONNECTOR HARNESS
Wire Connections to the Control Panel
Verify that VAM and other connected devices do not ex
ceed the
control’s Aux Power output capability. If it does, use a
supplementary power supply as shown.
IMPORTANT: When VAM is powered from an auxiliary power
supply, always apply power to the control panel first and then
VAM. Failure to observe this sequence results in improper
operation of VAM and may result in an ECP Error indication.
pwr_supp_conn-011-V0
BLACK
POWER FROM SUPPLEMENTARY
POWER SUPPLY IF USED
R
ED
BLACK
GREEN
YELLOW
CONTROL
TERMINAL STRIP
SUPPLEMENTARY
+12 VDC
POWER SUPPLY
P/N AD12612
DATA
IN
DATA
OUT
AUX
AUX
Supplementary Power Connections
Mount
VAM is for indoor use only and should be mounted near the control
panel or a keypad connected to the control panel for ease of wiring.
VAM mounts to a wall surface by hanging on two screws. See the
diagram below.
Leave the screw heads 1/8” above the wall surface.
If necessary, drill a hole in the wall for the wire harness to pass
through.
Connect the wire harness to the VAM before mounting.
MOUNTING SCREW
DRILL 3/16” DIA. HOLES 2 PLACES
1.65”
2.5”2.54”
vam-004-V0
Insert an SD/SDHC Memory Card
An SD card must be installed to receive automatic software
upgrades. The SD card can be left in the VAM. See Software
Upgrades section.
Avoid touching the contacts on the card
4GB SD card supplied
Supports up to 16GB SD Card
Insert the memory card (SD/SDHC Card) as shown.
INSERT
SD CARD
\
EXHIBIT 7-1
CFS8DLVAM / 573F-VAM
EXHIBIT 7-1
PLEASE GO TO THE BOTTOM OF
PAGE 7 FOR FCC / IC AGENCY
STATEMENTS.
Question and Answer IconNeed help?

Do you have a question about the Honeywell Vista Automation Module and is the answer not in the manual?

Honeywell Vista Automation Module Specifications

General IconGeneral
CompatibilityHoneywell Vista series control panels
Inputs/OutputsVaries depending on the specific module. Can include additional zones (hardwired or wireless), relay outputs, and trigger inputs.
Power Requirements12V DC
MountingInside Vista panel enclosure
User CodesUp to 48 user codes
Event LogStores up to 1000 events
FunctionExpands the capabilities of the Vista control panel by adding more zones, outputs, and automation features.

Summary

Make Wiring Connections

ECP Terminal Wiring

Connect VAM to control panel's ECP terminals using a 4-wire harness.

Mount the VAM

Wall Mounting Procedure

Mount VAM to wall surface by hanging on two screws.

SD Card Installation

Wi-Fi Network Setup

Connecting to Home Router

Steps to connect the VAM to your home Wi-Fi network.

Control Panel Programming

VAM Device Address Assignment

Assign an appropriate touchscreen device address (ECP) for VAM.

VAM Device Address Configuration

Setting VAM ECP Address

Configure the VAM's device address via its interface.

Time and Date Settings

Email Notification Setup

Total Connect Services Setup

Z-Wave Device Enablement

Enable Z-Wave devices for control via Total Connect.

Z-Wave Device Inclusion

Adding Z-Wave Modules

Steps to add Z-Wave devices like lights, locks, and thermostats.

Automation and Scene Creation

Custom Scene Definition

Define triggers, conditions, and actions for automated scenes.

Z-Wave Troubleshooting Guide

VAM as Secondary Controller

Software Update Procedures

Remote Access Setup

Related product manuals