Task Settings and Notes
Operation and Setup
External Discharge Function
The external discharge function uses the external high-power load resistor to quickly discharge
the battery accurately. When it is used, the battery to be discharged needs to be connected to the
input port, and the output is connected to the resister load. It is recommended that the resistance
of the load be between 1.5 and 2.5 ohms. Other resistance values can also be used normally, but
may not be able to operate at full power. When the external discharge is running, the load is very
hot. Please pay attention to safety and avoid accidents or personal injury.
10
D6 Pro AC/DC Dual Channel Smart Charger
Storage Function
When the storage function is selected, if the battery is lower than the preset storage voltage, the
charging task will be automatically performed; if the battery voltage is higher than the preset
storage voltage, the discharge task will be automatically performed. In order to save the task time,
the storage and discharge tasks do not accurately balance the cell voltage. There may be some
error between the cell voltage and the preset value at the end of the task, which is a normal
phenomenon.