The D6 Pro AC/DC Dual Channel Smart Charger is operation in a series charging mode. When
connecting the battery, the battery output cable must be connected. For lithium batteries, it is
strongly recommended to connect the balance ports for balanced charging so as to ensure that
the charger can accurately monitor the voltage of each cell and balance the cells with poor
consistency. When charging in unbalanced mode (without connecting to the battery balance
port), the charger will have a warning before starting the task.
09
D6 Pro AC/DC Dual Channel Smart Charger
Charge Function
When charging is in progress, the screen is marked in orange, and the screen turns green or blue
when charging is completed. When the charging is completed, the cell voltage difference is less
than 20mV, and the screen turns green. If you need to use it urgently, you can stop charging it. If
charging is not stopped at this time, the charger will continue to balance the battery. When the
voltage difference is less than 10mV, the screen will turn blue. When turned blue, the charger will
continue to accurately balance the battery.
After having the battery charged, the voltage will drop back due to the difference in performance
and this is normal. As the number of charging increases, the performance of the battery gradual-
ly declines, such a phenomenon will become obvious. Charging with a larger charging current will
also cause the voltage to fall back after a full charge, which is more obvious.
Tips: If you are charging outdoors, and you want to finish it quickly, you can stop charging when
you see the appearance of green state. When there is enough time, and you hope that the battery
can achieve a good balance, ,then wait for the blue color to appear, or wait for a while more after
the blue appear to get more accurate effect.
Discharge Function
The discharge function can discharge the battery. It is recommended to connect the balance port
for discharge, which is faster and the detection on discharge termination is more accurate. Due
to The limitation of the internal discharge power , the discharge process may be slower, which is
normal.