GAS BURNER SETTINGS
SERVICE MANUAL 67
REVISION 04/19, SW: 3.51
Adjustment “ETL” gas ovens (burner 2)
Houno Gas Oven Adjustment Settings Hot Air Burner 2 “Top”
O
2
%, CO
2
%
“MAX” RPM
O
2
%, CO
2
%
“MIN”, RPM
RPM Adjustment
normal operation
Air Proving
Switch - ON
Type of Gas
Heat
Power
BTU/hr
Ovn
Types
Gas inlet
Pressure
O
2
% CO
2
% RPM BTU/hr O
2
% CO
2
% RPM
“u17”
Min
“u17”
Start
“u17”
Max
OFF -> ON
NAT
(G20)
58000 1.06/5 3.2-8.0 in H
2
O
87000 1.10/8 3.2-8.0 in H
2
O
174000 1.20/15 3.2-8.0 in H
2
O 4.3% 9.3% 6300 87000 4.1% 9.4% 2700 2700 3900 6300 2300 +/-100
81800 2.06 3.2-8.0 in H
2
O
95500 2.10 3.2-8.0 in H
2
O
190000 2.20 3.2-8.0 in H
2
O 4.1% 9.4% 6600 95500 4.5% 9.2% 2800 2800 3600 6600 2300 +/-100
LP
(G31)
60000 1.06/5 5.2-14 in H
2
O
87000 1.10/8 5.2-14 in H
2
O
174000 1.20/15 5.2-14 in H
2
O 5.4% 10.2% 6300 87000 5.4% 10.2% 3900 3000 3900 6300 2300 +/-100
81800 2.06 5.2-14 in H
2
O
95500 2.10 5.2-14 in H
2
O
190000 2.20 5.2-14 in H
2
O 5.1% 10.4% 6600 95500 5.8% 9.9% 2900 2900 3600 6600 2300 +/-100