EasyManua.ls Logo

HP 200CD - Calibration Record

HP 200CD
35 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Calibration Record
Manufacture
r
Hewlett Packar
d
Model No.
Contract No.
Serial No.
Output connection: X Balanced Unbalanced
A
ll measurements to Hewlett Packard Model 334A Distortion Anal
y
ze
r
Load Resistance: 600 Ohms
Tes
t
Relative
Fre
q
uenc
y
% Harmonic Out
p
ut
(
Hz
)
Distortion
(
dB #
)
5
*
*
10
*
*
20
50
100
200
400
1,000
2,000
5,000
10 kHz
12.5 kHz
15 kHz
20 kHz
30 kHz
50 kHz
75 kHz
100 kH
200 kH
400 kH
750 kH
*
*
1 MHz *
*
1.25 MHz *
*
2 MHz *
*
4 MHz *
*
Notes: # Output flatness measured relative to 400 Hz. Zer
o
3.00 volts
* Denotes value beyond the range of the instrument under test.
** Denotes measurement limited by noise or capabilities of measuring instrument.
Maximum output level:
No load output voltage @ 400 Hz
2
0.00 volts
Loaded outpu
t
10.00 volt
s
at
6
00 ohms
0.17 watt
s
Date: Remarks/Repairs: ** Meter damping was not sufficient
for accurate reading.
Technician:
Test Conditions
Results
200 CD
Wireless Products Company
16 Round Pond Lane, Sag Harbor, NY 11963
Tel.: (631) 725-4400 Fax.: (631) 725-2223 E-mail: k2cby@aol.com

Related product manuals