  • P
    pharperAug 9, 2025
    How to fix build ink density calibration failure on HP Power Tool?
    • G
      gfreemanAug 9, 2025
      To address a build ink density calibration failure on your HP Power Tool: 1. Verify the Tank Ink Controller (TIC) is clean, especially the lenses area. 2. If needed, replace the TIC. 3. Dilute 200 ml (not more!) and add 200 ml of imaging oil. 4. Calibrate density. 5. Repeat the dilution until the density calibration passes.
  • P
    pbruceAug 15, 2025
    What to do for build ink conductivity calibration failure on HP Power Tool?
    • B
      Brian OlsonAug 15, 2025
      To address a build ink conductivity calibration failure on your HP Power Tool: 1. Set 1.7 in the Manual Density Calibration wizard. 2. Measure conductivity with an external measuring device, troubleshoot accordingly (target 50 ±10). 3. Perform manual conductivity calibration.
  • W
    woodjamesAug 19, 2025
    What to do if BID memories observed on HP Power Tool?
    • R
      rickbaileyAug 20, 2025
      If you observe image memory issues such as 'Casper,' a frame below the image, or general image memory problems with your HP Power Tool, first confirm the issue is only occurring on Silver prints. Then, use PrintCare to increase the Electrode Voltage (ELV) in steps of 50v. Alternatively, you can perform a Full Color Calibration (FCC) using the recommended Optical Density (OD) targets for your substrate.
  • J
    John RiversAug 25, 2025
    How to improve solid quality on HP Power Tool?
    • E
      Erica ZamoraAug 25, 2025
      If the solid quality is poor when using the HP Power Tool, first verify that the problem is only occurring on Silver prints. If so, use the Silver Color Adjustment wizard to increase the Electrode Voltage (ELV) in steps of 50v. Alternatively, perform a full color calibration (FCC) with recommended OD targets per substrate.
  • L
    longtaraAug 30, 2025
    What to do if TE band appears on HP Power Tool?
    • J
      Judith LewisAug 30, 2025
      If you notice a TE band, which is silver accumulation at the trailing edge area on your HP Power Tool prints, calibrate the BID engage if it's not symmetrical between the front and rear. Also, in overlap prevention settings, increase the leading edge by 10 mm or more. Consider using leading edge color variation correction found in Print Care Center > Maintenance > Component Calibrations.
  • A
    April PhillipsSep 3, 2025
    How to fix high background on HP Power Tool?
    • J
      Jennifer MartinSep 3, 2025
      If the background is too high when using the HP Power Tool, use the Silver Color Adjustment wizard. First, verify that the electrode voltage (ELV) is at the lowest setting (400 v). Then, optimize the cleaner voltage (CLV) for memory defects improvement by using PrintCare to print CLV values of 220, 240, 260, 280, and 300.

HP Indigo 6600 Specifications

General IconGeneral
Print speedNot applicable
Image resolutionNot applicable
Line screensNot applicable
Maximum sheet sizeNot applicable
Minimum sheet sizeNot applicable
Image sizeNot applicable
Paper weightNot applicable
Paper thicknessNot applicable
FeederNot applicable
StackerNot applicable
Print Engine DimensionsNot applicable
Print Engine WeightNot applicable

Related product manuals