EasyManuals Logo
Home>HP>Server>4X - DDR InfiniBand Mezzanine HCA

HP 4X - DDR InfiniBand Mezzanine HCA User Manual

HP 4X - DDR InfiniBand Mezzanine HCA
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #73 background imageLoading...
Page #73 background image
Troubleshooting 73
Memory problems
General memory problems are occurring
Action:
Isolate and minimize the memory configuration. Use care when handling DIMMs ("DIMM handling
guidelines" on page 53).
o Be sure the memory meets the server requirements and is installed as required by the server.
Some servers may require that memory banks be populated fully or that all memory within a
memory bank must be the same size, type, and speed. To determine if the memory is installed
properly, see the server documentation.
o Check any server LEDs that correspond to memory slots.
o If you are unsure which DIMM has failed, test each bank of DIMMs by removing all other
DIMMs. Then, isolate the failed DIMM by switching each DIMM in a bank with a known working
DIMM.
o Remove any third-party memory.
To test the memory, run HP Insight Diagnostics (on page 42).
Server is out of memory
Action:
1. Be sure the memory is configured properly. Refer to the application documentation to determine the
memory configuration requirements.
2. Be sure no operating system errors are indicated.
3. Be sure a memory count error ("Memory count error exists" on page 73) did not occur. Refer to the
message displaying memory count during POST.
Memory count error exists
Possible Cause: The memory modules are not installed correctly.
Action:
1. Be sure the memory modules are supported by the server. See the server documentation.
2. Be sure the memory modules have been installed correctly in a supported configuration. See the
server documentation.
3. Be sure the memory modules are seated properly ("DIMM handling guidelines" on page 53).
4. Be sure no operating system errors are indicated.
5. Restart the server and check to see if the error message is still displayed.
6. Run HP Insight Diagnostics (on page 42). Then, replace failed components as indicated.
Server fails to recognize existing memory
Action:
1. Reseat the memory. Use care when handling DIMMs ("DIMM handling guidelines" on page 53).
2. Be sure the memory is configured properly. See the server documentation.

Table of Contents

Other manuals for HP 4X - DDR InfiniBand Mezzanine HCA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 4X - DDR InfiniBand Mezzanine HCA and is the answer not in the manual?

HP 4X - DDR InfiniBand Mezzanine HCA Specifications

General IconGeneral
BrandHP
Model4X - DDR InfiniBand Mezzanine HCA
CategoryServer
LanguageEnglish

Related product manuals