Troubleshooting 76
o
For rack-mounted servers, check the cables to the KVM switch and be sure the switch is correctly
set for the server. You may need to connect the monitor directly to the server to be sure the KVM
switch has not failed.
o For tower-model servers, check the cable connection from the monitor to the server, and then
from the server to the power outlet.
5. Press any key, or type the password, and wait a few moments for the screen to activate to be sure
the energy saver feature is not in effect.
6. Be sure the video driver is current. Refer to the third-party video adapter documentation for driver
requirements.
7. Be sure a video expansion board has not been added to replace onboard video, making it seem like
the video is not working. Disconnect the video cable from the onboard video, and then reconnect it
to the video jack on the expansion board.
NOTE: All servers automatically bypass onboard video when a video expansion board is
present.
8. Press any key, or type the password, and wait a few moments for the screen to activate to be sure
the power-on password feature is not in effect. You can also tell if the power-on password is enabled
if a key symbol is displayed on the screen when POST completes.
If you do not have access to the password, you must disable the power-on password by using the
Password Disable switch on the system board. Refer to the server documentation.
9. If the video expansion board is installed in a PCI Hot Plug slot, be sure the slot has power by
checking the power LED on the slot, if applicable. Refer to the server documentation.
10. Be sure the server and the operating system support the video expansion board.
Monitor does not function properly with energy saver features
Action: Be sure the monitor supports energy saver features, and if it does not, disable the features.
Video colors are wrong
Action:
Be sure the 15-pin VGA cable is securely connected to the correct VGA port on the server and to the
monitor.
Be sure the monitor and any KVM switch are compatible with the VGA output of the server.
Slow-moving horizontal lines are displayed
Action: Be sure magnetic field interference is not occurring. Move the monitor away from other monitors
or power transformers.
Audio problems
Action: Be sure the server speaker is connected. Refer to the server documentation.

Table of Contents

Other manuals for HP 4X - DDR InfiniBand Mezzanine HCA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP 4X - DDR InfiniBand Mezzanine HCA and is the answer not in the manual?

HP 4X - DDR InfiniBand Mezzanine HCA Specifications

General IconGeneral
BrandHP
Model4X - DDR InfiniBand Mezzanine HCA
CategoryServer
LanguageEnglish

Related product manuals