Model
5328A
General Information
Table
7-3.
Specifications (Continued)
DIGITAL VOLTMETER MEASUREMENTS
TOTALIZING AND SCALING MEASUREMENTS
DVM (option
020
and
021)
-
Trigger levels of input channels
A and
0
and external voltages may be measured.?
Start A (standard and option
040)
-
The number of counts at
the A input are totalized for N=l on the resolution switch.
For N >1, A/N is totalized and the scaled output (A/N)
IS
available at the Timebase Out rear panel connector.
Range:
0
-
100 MHz for N=l
0
-
10 MHz for N >1
Maxlmum Sensltlvlty: OPT.
020
OPT. 021
Meas. T~rne (N=).
10
s
(~=107
1 s (N=106)
o
i
s
(N=IO~)
10 rns (~=109
1 rns (N=103)
EVENTS C, A TO B (standard and option
040)
-
The number
of events at the C Input are totallzed during the synchron~zed
time Interval (~.e., a multiple of 100 ns. or 10 ns for opt. 040)
defined by inputs to channel A and B.
Accuracy:
+1 count of C
i
trlgger error' of A and B+
freq. of C x 120 ns
(il count of C
+
trigger error* of A and Bi freq. of C
x 12 ns w~th opt. 040)
Range:
0 tok125 Vdc
i10, ~100,IlOOO Vdc,
and AUTORANGE
Full range dlsplay
reaolutlon
(1 sec
measurement time)
ME.A.SU!?E?s!ENTS
W!T!-!
DELAY
(Optinn
040)
Accuracy:
(20 mln. warm-up)
2.03% readmg
i
004%
range, for 1000 V
range.
i
087% read~ng
i
.004% range
Delay mode
IS
act~vated by Inner concentric knob on LEVEL A
control of optlon 040 Un~versal Module (red LED ~ndicates
delay
IS
act~vated)
In delay mode Channel A trlggers and is
then d~sabled from trlggerlng agaln unt~l the delay times out
(d~sabled state occurs w~th~n 1 ys after tr~gger~ng)
Channel B
IS
cont~nuously d~sabled unt~l the delay tlmes out
After the
delay, both A and B are enabled The delay t~me may be
measured by plac~ng the counter ln T I A--B and the Un~versal
Module In check
(CHK)
Temp. Coefflclent:
(0 to 40"
C)
lnput Terminals:
Single ended
lo
MO
lnput Impedance:
Delay range:
20ys to 20 ms continuously adjustable
Normal Mode
Rejection
Ratio:
Minimum Dead Time:
1 ys between stop and next start (T I
average measurements only)
Meaningful Functions:
FREQ
A,
PER A. PER AVG A, T.I.
A-B, T.I. AVG A-6, RATIO C/A. START
A,
EVENTS C, A+B
>60dBat60 Hz
(50 Hz)
i
0 1%
>80
dB
at 50 Hz or
greater wlth fllter on
Effective Common
Mode Relectlon Ratio
(1
ka
unbalance).
DC-
>I20 dB
AC
>I20
dB
for
mult~ples of 60
Hz
(50
Hz) wlth fllter on
HP-I8 INTERFACE (Option
011)
Prov~des digital output of measurement data ("talker") as well
as input for remote program control ("l~stener").
Programmable Functions:
Funct~on. Resolution, Sample rate
(max, or manual control), Arming. Display modes, Meas-
urement modes, Output modes, and Reset commands
HP-IB commands:
responds to the following bus com-
mands (see HP-IB Users Guides for def~nitions)
-
Unlisten,
Untalk, Local Lockout, Dev~ce Clear, Serial Poll Enable.
Serial Poll Disable, Go to Local, Selected Device Clear,
and Group Executive Trigger.
Sewice Request (SRQ):
if enabled, Indicates end of
measurement.
Maximum data output rate:
500 readings/sec
Response The
(step Input)
70 rns 10 ms (fllter off)
Maximum lnput
HI
to LO ?I100 V all
ranges, LO to chass~s
ground.?500 V
Trigger Level
Measurements:
1 mV d~splay
resolut~on: trlgger level
read~ng
automatically
rnult~pl~ed by settlng of
attenuator swltch ~f
uslng optlon
040
unl-
versa1 module