Table 6-8 Error Codes (continued)
ReasonErrorCode
The controller specified is not specified correctly.
Controller '%s' is invalid
2819
The controller specified was not detected.
Could not detect Controller '%s'
2820
Invalid Method value.
Invalid Method
2818
Invalid Controller value.
Invalid Controller
2819
The specified Read Cache/Write Cache Ratio is not supported
either by the controller or the current controller configuration.
Invalid Read Cache/Write Cache
Ratio
2822
The specified Rebuild Priority is not supported.
Invalid Rebuild Priority
2823
The specified Expand Priority is not supported. Also, this
error occurs if the controller does not allow expansion and
therefore does not support Expand Priority.
Invalid Expand Priority
2824
Invalid Surface Scan Delay
Invalid Surface Scan Delay
2857
The specified ClearConfigurationWithDataLoss parameter
is not correct.
Invalid
ClearConfigurationWithDataLoss
parameter
2849
The Array ID is invalid.
Invalid Array
2825
The array command is missing from the script file. Some
commands were found that require an array to work on.
Array not specified
2826
The Array ID in the script file does not match the Array ID
of the newly created array. For example, if you have Array
New Array ID does not match the
next available Array ID
2827
A already and the script file tries to create Array C (without
Array B), the script generates this error.
When running in Configure mode, this error happens when
the Array ID in the script file already exists in the
configuration. Configure mode can only create new arrays.
New Array ID already exists
2828
The controller does not allow a new array to be created. This
could be because there are no unassigned physical drives on
Cannot create Array
2829
the controller, or the maximum number of arrays or logical
drives has already been reached.
The array could not be expanded. This could be because the
controller does not support expansion, or the current
configuration does not allow expansion to occur on the array.
Cannot expand Array
2830
The spare state of the array could not be changed. This can
happen when you are trying to add a spare or drop a spare.
Cannot change Array Spare
2831
The current configuration does not allow a spare state change
for the array.
The physical drive listed for the array is not a valid physical
drive, or it is a physical drive that is not capable of being
placed in the array.
Invalid Physical Drive
2832
The spare drive listed for the array is not a valid spare drive,
or it is a drive that is not capable of being placed on the array
as a spare.
Invalid Spare
2833
One or more drives are not listed in an existing array. This
is illegal because removing physical drives from a configured
array causes data loss.
Cannot remove Physical Drives
from existing array
1053
This error message can occur if the user is attempting to add
an odd number of drives to an existing array that has RAID
Array requires an odd number of
drives
1052
1 logical drives. If the controller has RAID 1 logical drives
and supports RAID 1 -> RAID 5/RAID ADG migration, this
cpqacuxe 63