Appendix A The Error Codes
1000h – 100Dh: Multiple Processor Error Codes
100Ch Memory map I/O access test failed on
processor X at address XXXXXXXXh.
Processor error.
Install a new processor.
100Dh Application processors were not
detected.
Processor error.
Check that the processor is correctly configured.
If the error persists, install new processor.
100Eh CPU speed error. Processor speed error.
Check processor Speed stamp and clocks.
If the error persists, install new processor.
100Fh CPU count error. Processor error.
Check number of processors present.
1010h Configuration access mechanism test
failed.
Check processor, L2 cache and main memory are
correctly installed.
If problem persists, install new:
L2 memory (if installed in accessory slot), or
processor (if integrated on the processor card).
1011h TagRAM control register read failed. Check processor, L2 cache and main memory are
correctly installed.
If problem persists, install new:
L2 memory (if installed in accessory slot), or
processor (if integrated on the processor card).
1012h TagRAM control register write failed. Check processor, L2 cache and main memory are
correctly installed.
If problem persists, install new:
L2 memory (if installed in accessory slot), or
processor (if integrated on the processor card).
1013h Value read back from TagRAM control
register is not the same as the value
written.
Check processor, L2 cache and main memory are
correctly installed.
If problem persists, install new:
L2 memory (if installed in accessory slot), or
processor (if integrated on the processor card).
Code Explanation Details/Parts to Check