Chapter 5
Replacing components
Replacing components
This chapter describes how to remove and install the following components in the HPEAruba Networking 6300M
Switch Series:
n Power supply
n Fan tray
There are no user-replaceable parts on the HPEAruba Networking 6300F Switch Series.
The 6300M switches and their components are sensitive to static discharge. Use an antistatic wrist strap and observe all
static precautions when replacing components.
If a power supply must be removed, and then reinstalled, wait at least 5 seconds before re-installation. Otherwise,
damage to the switch may occur. The power supply needs this time to bleed off any retained power.
Replacing the fan
If a fan has failed, the fan LED will flash simultaneously with the switch Fault LED. Replace the failed component as
soon as possible.
JL762A (HPEAruba Networking 6300M 48G Pwr2Prt 2F 1PS Bdl) has power-to-port (back-to-front) airflow and requires two
JL761A (Aruba 6300M Power-to-Port Fan Tray). Other 6300M fan trays are not supported in the JL762A switch. All other
6300 switches have port-to-power (front-to-back) airflow; JL761A fan trays are not supported in any other 6300M switch
other than the JL762A.
To Remove an Existing Fan:
HPE Aruba Networking CX 6300 Switch Series | Installation and Getting Started Guide