8. Loosen the T-10 uncapping screw sufficiently so you can manually move the Carriage Assembly
in step 9.
9. Push the Carriage Assembly into the print path to gain access to two T-15 screws that secure the
Service Station to the Carriage Rail.
10. Use a allen key provided in the tool kit to remove two allen screws that secure the Service Station
to the Carriage Rod.
NOTE: Support the Service Station so it does not fall when you remove the attachment screws.
216 Chapter 6 Removal and Installation ENWW