Sheets of A3 or tabloid paper
An explosion-protected vacuum cleaner compliant with the following normative specications:
Europe/IEC: Zone 22 or better, 200°C (392°F) or less
US/NEC: Class II, division 2, 200°C (392°F) or less
And with the following additional specications:
Air ow: 250 m³/h (147 ft³/min)
Depression: 19.6 kPa (2.84 psi)
Power: 1800 W (2.4 hp)
A ladder
A temperature and humidity sensor with data logger
Personal protective equipment for users and service engineers, according to your environmental, safety,
and regulatory guidelines
Lift trolley for moving external tanks and material loading tanks
Static earthing clamps
You are required to use static earthing clamps when using material loading tanks and/or an external
tank.
Pallet jack
Transportation tools to move the systems
TIP: The number of cartridges given above is the minimum required for installation. HP recommends
purchasing more cartridges of each type so that you can continue printing after installation.
Extra requirements for the 4210 with material loading tank
Drum rotator
You are recommended to use an explosion-protected drum rotator to operate with combustible
dusts, compliant with the following normative specications:
Europe/IEC: Zone 22 or better, 200°C (392°F) or less
US/NEC: Class II, division 2, 200°C (392°F) or less
The drum rotator is required to ensure proper grounding for the drum while rotating. It should be
activated before the material loading tank is used to supply fresh material to the processing station.
The recommended rotation speed is 20 rpm (total rotation time for material loading tank preparation
is 90 s).
Interface to processing station