HP P2000 G3 MSA System Event Descriptions Reference Guide 33
208
Info. A scrub-disk job has started for the indicated disk. The result will be logged with event 209.
Recommended actions
• No action is required.
209
Error A scrub-disk job logged with event 208 has completed and found one or more media errors, SMART
events, or hard (non-media) errors. If this disk is used in a non-fault-tolerant vdisk, data may have been lost.
Recommended actions
• Replace the indicated disk.
Warning A scrub-disk job logged with event 208 has been aborted by a user, or has reassigned a disk block. These
bad-block replacements are reported as "other errors". If this disk is used in a non-fault-tolerant vdisk, data
may have been lost.
Recommended actions
• Monitor the error trend and whether the number of errors approaches the total number of bad-block
replacements available.
Info. A scrub-disk job logged with event 208 has completed and found no errors, or a disk being scrubbed (with
no errors found) has been added to a vdisk, or a user has aborted the job.
Recommended actions
• No action is required.
210
Info. All snapshots have been deleted for the indicated master volume or snap pool.
Recommended actions
• No action is required.
211
Warning SAS topology has changed; no elements are detected in the SAS map. The message specifies the number
of elements in the SAS map, the number of expanders detected, the number of expansion levels on the
native (local controller) side and on the partner (partner controller) side, and the number of device PHYs.
Recommended actions
• Perform a rescan to repopulate the SAS map.
• If a rescan does not resolve the problem, then shut down and restart both controllers.
• If the problem persists, see “Resources for diagnosing and resolving problems” in the SMU help for the
System Events panel, or the CLI help for the show events command.
Info. SAS topology has changed; the number of SAS expanders has increased or decreased. The message
specifies the number of elements in the SAS map, the number of expanders detected, the number of
expansion levels on the native (local controller) side and on the partner (partner controller) side, and the
number of device PHYs.
Recommended actions
• No action is required.
212
Info. All master volumes have been deleted for the indicated snap pool.
Recommended actions
• No action is required.