Replacing memory DIMMs
About this task
Follow the steps below to replace a defective DL360/380G9 4GB RDIMM.
Procedure
1. Power down the server.
Follow Application power down procedures, if applicable.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Extend the server from the rack.
4. Remove the access panel.
5. Remove the DIMM.
6. To replace the component, reverse the removal procedure.
Related links
DIMM problems on page 33
RAID Battery
The RAID battery is customer replaceable unit (CRU). The RAID battery is not covered under the
maintenance agreement. The customer must order the RAID Battery by calling the appropriate
Order Entry Fulfillment Collections (OEFC) center as listed in the following table.
RAID Battery
November 2015 Maintaining and Troubleshooting the HP ProLiant DL360 G9 Server 35