Item Description Status
1 Power On/Standby
Button/LED
Solid Green = System is on
Flashing Green = Waiting for server power sequence
Solid Amber = System is in standby, but power is still applied
Off = Power cord is not attached, power supply failure has occurred,
no power supplies are installed, facility power is not available or the
power button cable is disconnected
2 Health LED Solid Green = System health is normal
Flashing Green = Power fault (check system and devices). See HP
ProLiant DL360 Gen9 Server User Guide.
Flashing Amber = System health is degraded. To identify the
component in a degraded state, see Diagnosing system faults using
HP ProLiant DL360 G9 Server console on page 12.
Flashing Red = System health is critical. To identify the component
in a critical state, see
Diagnosing system faults using HP ProLiant
DL360 G9 Server console on page 12. If possible check iLO/BIOS
logs. Also check application’s system log and SEL log from IPMI
interface if possible.
3 NIC Status LED Solid Green = Link to network
Flashing Green = Network active
Off = No network connection or activity
4 UID button/LED Solid Blue = Identification is activated
Flashing Blue = System is being managed remotely or firmware
upgrade is in progress
Off = Identification is deactivated
Front panel LEDs of HP ProLiant DL360 G9 Server