Hardware options installation 60
To install the component:
1. Back up all data.
2. Close all applications.
CAUTION: In systems that use external data storage, be sure that the server is the first unit to be
powered down and the last to be powered back up. Taking this precaution ensures that the system
does not erroneously mark the drives as failed when the server is powered up.
3. Power down the server (on page 23).
4. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
5. Extend the server from the rack (on page 23).
6. Remove the access panel (on page 24).
7. Install the FBWC module ("Installing the flash-backed write cache module" on page 58), if it is not
already installed.
8. Connect the capacitor pack cable to the connector on the top of the cache module.