Systems Insight Display LEDs and internal health LED
er amber or red, the server is experiencing
ate system
combinations
When the internal health LED on the front panel illuminates eith
a health event. Combinations of illuminated system LEDs and the internal health LED indic
status.
Systems Insight Display
LED and color
Internal health
LED color
Status
Processor (amber) Red One or more of the following co
• Processor in socket X has failed.
• Processor X is not installed in t
nditions may exist:
he socket.
• Processor X is unsupported.
• ROM detects a failed processor during POST
Amber Processor in socket X is in a pre-failure condition.
DIMM (amber) Red DIMM in slot X has failed.
Amber DIMM in slot X is in a p ilure condition. re-fa
DIMM (amber) Red One or more DIMMs have failed. Test each bank of
DIMMs by removing al er DIMMs. Isolate the failed
DIMM by replacing eac in a bank with a known
working DIMM.
l oth
h DIMM
Overtem r The Health Driver has detected a cautionary temperature
level.
perature (amber) Ambe
Red The server has detected a hardware critical temperature
level.
Fan (am Amber One fan is failed or rem ber) oved.
Red Two or more fans have failed or are missing.
Power su Red Only one power supply installed and power supply in
standby.
• Power supply fault
• System board fault
pply (amber)
P Amber Redundant power supply installed and only one power
supply is functional.
• AC power cord not plugged into redundant power
supply
• Redundant power supply fault
ower supply (amber)
Power supply (amber) Amber Power supply mismatch at POST or power supply mismatch
through hot add.
Component identification 69