HP 460W Factory Integrated Power Supply Kit
Part Number
500447-B21
Operational Input Voltage Range (Vrms)
90 to 135 and 180 to 264 V ac full ranging
Frequency Range (Nominal) (Hz)
47 to 66 Hz
Nominal Input Voltage (Vrms)
100 115 208 220 230 240
Max Rated Output Wattage Rating
460 460 460 460 460 460
Nominal Input Current (A rms)
10 10 5 5 5 5
Max Rated Input Wattage Rating (Watts)
760 760 700 700 700 700
Max. Rated VA (Volt-Amp)
850 850 830 830 830 830
Efficiency (%)
65 65 65 65 65 65
Power Factor
0.9 0.9 0.9 0.9 0.9 0.9
Leakage Current (mA)
3.5mA 3.5mA 3.5mA 3.5mA 3.5mA 3.5mA
Maximum Inrush Current (A peak)
450 450 450 450 450 450
Maximum Inrush Current duration (mS)
HP 750W Common Slot Gold Hot Plug Power Supply Kit (Optional)
Part Number
512327-B21
HP RPS Enablement Kit Part Number
508544-B21
Input Voltage Range ( V rms)
100 to 240
Frequency Range (Nominal) (Hz)
50/60
Nominal Input Voltage (Vrms)
100 120 200 208 220 230 240
Maximum Rated Output Wattage Rating
750 750 750 750 750 750 750
Nominal Input Current (A rms)
8.9 7.4 4.3 4.1 3.9 3.7 3.6
Maximum Rated Input Wattage Rating (Watts)
857 847 824 824 820 820 820
Maximum Rated VA (Volt-Amp)
894 884 859 854 854 854
Efficiency (%)
87.5 88.5
91 91
91.5 91.5 91.5
Power Factor
0.97
Leakage Current (mA)
0.42 0.50
.83
0.87 0.92 0.96 1.00
Maximum Inrush Current (A peak)
30
Maximum Inrush Current duration (mS)
20
Maximum British Thermal Unit Rating (BTU-Hr)
2925 2892 2812 2812 2797 2797 2797