Using CCI with Hitachi and other storage systems
Table 11 (page 30) shows the related two controls between CCI and the RAID storage system type
(Hitachi or HP XP). Figure 6 (page 31) shows the relationship among the application, CCI, and
RAID storage system.
• The following common HP API/CLI commands are rejected with EX_ERPERM(*1) by connectivity
of CCI with the RAID storage system:
horctakeover
paircurchk
paircreate
pairsplit
pairresync
pairvolchk
pairevtwait
pairdisplay
raidscan (except -find option only), raidar
raidvchkset
raidvchkdsp
raidvchkscan
• The following HP API/CLI commands are rejected with EX_ERPERM(*2) on HITACHI storage
system even when both CCI and HP RAID Raid Manager are installed:
pairvolchk -s
pairdisplay -CLI
raidscan -CLI
paircreate -m noread for Continuous Access Synchronous
paircreate -m dif/inc for Business Copy
Table 11 Relationship between CCI and RAID storage system
XP API/CLICommon API/CLIRAID systemInstallation orderCCI version
Cannot use (except
CLI)
EnableHitachiCCICCI 01-08-03/00 or later
EX_ERPERM(*1)HP
EnableHitachiInstall CCI after installing
RAID Manager
EnableHP
EnableEnableHPRAID ManagerHP RAID Manager
01.08.00 or later
EX_ERPERM(*2)EX_ERPERM(*1)Hitachi
EnableEnableHPInstall RAID Manager after
installing CCI
EX_ERPERM(*2)EnableHitachi
30 Installation requirements