2. Execute the following command:
$ PRODUCT INSTALL RM /source=Device:[PROGRAM.RM.OVMS]/LOG -
_$ /destination=SYS$POSIX_ROOT:[000000]
Device:[PROGRAM.RM.OVMS] where HITACH-ARMVMS-RM-V0122-2-1.PCSI exists
3. Verify installation of the proper version using the raidqry command:
$ raidqry -h
Model: RAID-Manager/OpenVMS
Ver&Rev: 01-22-03/06
Usage: raidqry [options]
4. Follow the requirements and restrictions in “Porting notice for OpenVMS” (page 19).
Command execution by in-band and out-of-band methods
The methods of executing commands provided by RAID Manager can be classified into the in-band
and out-of-band methods.
In-band method. This method transfers a command from the client or the server to the command
device of the storage system via SVP and executing a RAID Manager operation instruction.
Out-of-band method. This method transfers a command from the client or the server to the
virtual command device in the SVP via LAN, assigning a RAID Manager operation instruction
to the DKC, and executing it.
For executing a command by the in-band and out-of-band methods, a command device or a virtual
command device is set in a configuration definition file as shown in the following figure, an IP
address of the SVP is specified in the configuration definition file.
The following figure shows a system configuration example and a setting example of a command
device and a virtual command device by the in-band and out-of-band methods.
Command execution by in-band and out-of-band methods 37