$1$DGA147 0 F CL2-H 0 3 30009 147 OPEN-9
$1$DGA148 0 F CL2-H 0 4 30009 148 OPEN-9
$ pairdisplay -g BCVG -fdc
Group PairVol(L/R) Device_File M ,Seq#,LDEV#..P/S,Status, % ,P-LDEV# M
BCVG oradb1(L) $1$DGA146 0 30009 146..P-VOL PAIR, 100 147 -
BCVG oradb1(R) $1$DGA147 0 30009 147..S-VOL PAIR, 100 146 -
$
$ pairdisplay -dg $1$DGA146
Group PairVol(L/R) (Port#,TID, LU-M) ,Seq#,LDEV#..P/S,Status, Seq#,P-LDEV# M
BCVG oradb1(L) (CL1-H , 0, 2-0) 30009 146..P-VOL PAIR,30009 147 -
BCVG oradb1(R) (CL1-H , 0, 3-0) 30009 147..S-VOL PAIR,----- 146 -
$
Startup procedures in bash
RAID Manager should not be used through the bash, because the bash is not provided as an
official release in OpenVMS 7.3-1.
(1) Create the shareable Logical name for RAID if undefined initially.
You need to define the Physical device ($1$DGA145…) as either DG* or DK* or GK* by using
the SHOW DEVICE command and the DEFINE/SYSTEM command, but then it does not need to be
mounted.
$ show device
Device Device Error Volume Free Trans Mnt
Name Status Count Label Blocks Count Cnt
$1$DGA145: (VMS4) Online 0
$1$DGA146: (VMS4) Online 0
:
:
$1$DGA153: (VMS4) Online 0
$$ DEFINE/SYSTEM DKA145 $1$DGA145:$ DEFINE/SYSTEM DKA146 $1$DGA146:::$ DEFINE/SYSTEM DKA153 $1$DGA153:
(2) Define the RAID Manager environment in LOGIN.COM.
If RAID Manager and HORCM are executing in different jobs (different terminal), then you must
redefine LNM$TEMPORARY_MAILBOX in the LNM$PROCESS_DIRECTORY table as follows:
$ DEFINE/TABLE=LNM$PROCESS_DIRECTORY LNM$TEMPORARY_MAILBOX LNM$GROUP
(3) Discover and describe the command device on /etc/horcm0.conf.
bash$ inqraid DKA145-151 -CLI
DEVICE_FILE PORT SERIAL LDEV CTG H/M/12 SSID R:Group PRODUCT_IDDKA145 CL1-H 30009 145 - - -
- OPEN-9-CM
DKA146 CL1-H 30009 146 - s/S/ss 0004 5:01-11 OPEN-9
DKA147 CL1-H 30009 147 - s/P/ss 0004 5:01-11 OPEN-9
DKA148 CL1-H 30009 148 - s/S/ss 0004 5:01-11 OPEN-9
DKA149 CL1-H 30009 149 - s/P/ss 0004 5:01-11 OPEN-9
DKA150 CL1-H 30009 150 - s/S/ss 0004 5:01-11 OPEN-9
DKA151 CL1-H 30009 151 - s/P/ss 0004 5:01-11 OPEN-9
/etc/horcm0.conf
HORCM_MON
#ip_address service poll(10ms) timeout(10ms)
127.0.0.1 52000 1000 3000
HORCM_CMD
#dev_name dev_name dev_nameDKA145
HORCM_DEV
#dev_group dev_name port# TargetID LU# MU#
HORCM_INST
#dev_group ip_address service
You will have to start HORCM without a description for HORCM_DEV and HORCM_INST because
target ID & Lun are Unknown.
You can determine a mapping of a physical device with a logical name easily by using the raidscan
-find command option.
(4) Execute ‘horcmstart 0’ as background.
bash$ horcmstart 0 &
18
bash$
starting HORCM inst 0