Control panel message Description Recommended action
4.
If the error persists, replace the system
board.
00C-PMM Deallocation Error during MEBx
Cleanup
Memory error during POST execution of the
Management Engine (ME) BIOS Extensions
option ROM.
1.
Reboot the computer.
2.
Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3.
If the memory conguration was recently
changed, unplug the power cord, restore
the original memory conguration, and
reboot the computer.
4.
If the error persists, replace the system
board.
00D-Setup Error during MEBx Execution MEBx selection or exit resulted in a setup
failure.
1.
Reboot the computer.
2.
Unplug the power cord, re-seat the
memory modules, and reboot the
computer.
3.
If the memory conguration was recently
changed, unplug the power cord, restore
the original memory conguration, and
reboot the computer.
4.
If the error persists, replace the system
board.
00E-Inventory Error during MEBx Execution BIOS information passed to the MEBx resulted
in a failure.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version.
3.
If the error still persists, replace the
system board.
00F-Interface Error during MEBx Execution MEBx operation experienced a hardware error
during communication with the ME.
1.
Reboot the computer.
2.
If the error persists, update to the latest
BIOS version.
3.
If the error still persists, replace the
system board.
100-Front Audio Not Connected Front audio cable has been detached or
unseated from system board.
Reconnect or replace front audio cable.
2E1-MemorySize Error Memory amount has changed since the last
boot (memory added or removed).
The system memory size is dierent from the
last startup. The most common reason is the
removal of memory from the system board.
Press the F1 key to save the memory changes.
If this message persists, verify that the
memory modules are installed correctly.
2E2-Memory Error Memory module conguration failed during
boot up.
1.
Ensure memory modules are correctly
installed.
2.
Verify proper memory module type.
3.
Remove and replace the identied faulty
memory module(s).
4.
If the error persists after replacing
memory modules, replace the system
board.
POST error messages and diagnostic front panel LEDs and audible codes 63