EasyManuals Logo

HPE BladeSystem c7000 User Manual

HPE BladeSystem c7000
14 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
4
4.
Install the rear cage into the enclosure, close the hinges, and
tighten the thumbscrews.
Enclosure bay identification
Before installing front or rear components into the enclosure, review
enclosure bay numbering for each component.
Full-height device bay numbering
Half-height device bay numbering
Power supply bay numbering
Fan bay numbering
Installing the front components
CAUTION: To prevent improper cooling and thermal
damage, do not operate the enclosure unless all bays
are populated with a component or a blank.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE BladeSystem c7000 and is the answer not in the manual?

HPE BladeSystem c7000 Specifications

General IconGeneral
Form Factor10U
Interconnect Bays8
Blade Slots16 half-height or 8 full-height
Device Bays16 half-height blade server bays or 8 full-height blade server bays
Power SuppliesUp to 6 hot-plug power supplies
Cooling Fans10 hot-plug fans
ManagementOnboard Administrator
Height17.5 inches
Width17.6 inches
CompatibilityHPE ProLiant and Integrity server blades
Non-operating Temperature-40° to 70°C (-40° to 158°F)
Operating Humidity10% to 90% (non-condensing)
Non-operating Humidity5% to 95% (non-condensing)
NetworkingDependent on installed interconnect modules
Operating Temperature10° to 35°C (50° to 95°F)

Related product manuals