WARNING: To reduce the risk of personal injury or
damage to equipment:
Extend the leveling jacks to the floor.
Ensure that the full weight of the rack rests on
the leveling jacks.
Install the rack stabilizer kit on the rack.
Extend only one rack component at a time.
Racks might become unstable if more than one
component is extended.
WARNING: This robotic assembly requires library
firmware version 3200 or later. It will not operate
with earlier firmware versions. Before installing this
robotic assembly, ensure that the library is running
version 3200 or later.
Process overview
Prerequisites
Tools required
2 small flathead screwdrivers or Torx drivers
#2 Phillips screwdriver
Procedure
1. Power off the library
2. Remove the magazines
3. Prepare to remove the robotic assembly and
spooling mechanism from the base module
4. Remove the robotic assembly and spooling
mechanism from the base module
5. Install the robotic assembly and spooling
mechanism into the base module
6. Completing the robotic assembly and spooling
mechanism installation
7. Power on the library
8. Verify the replacement procedure
Powering off the library
Procedure
1. Verify that all host processes are idle.
2. Depress the power button on the front panel for 5
seconds and then release it.
If the library is idle, you can release the button when
the Ready LED begins flashing.
If the library does not perform a soft shutdown, press
and hold the power button for 10 seconds.
3. If the library has multiple modules, verify that the
robotic assembly is in its parked position behind the
OCP.
IMPORTANT: Continuing this procedure when
the robotic assembly is not in its parked position
could damage library components.
a. Look though the expansion module windows to
locate the robotic assembly.
b. If you cannot see the robotic assembly through
the windows, remove one of the magazines in the
base module and look through the magazine
opening.
c. If you cannot locate the robotic assembly or it is
not in its parked position behind the OCP, see the
user guide for troubleshooting information.
Removing the magazines
Procedure
1. Insert a small flat head screwdriver or Torx driver into
the appropriate magazine release hole and gently
push the latch in.