Chapter 10 Parameter Shenzhen Hpmont Technology Co., Ltd.
-82- HD09 Series User Manual V1.1
Ref. Code
Function
Setting Range
Default
Unit
Attribute
Setting
F19.37
Frequency adjust range
selection
Unit: Main frequency range
0: 0- max. frequency
1: Negative maximum frequency to
maximum frequency
Ten: Unused
Hundreds: The range of synthetic
frequencies
0: 0 - up limitation frequency
1: Negative upper limit frequency to
upper limit frequency
100 1
F19.38
Phase short circuit
detection action selection
0: No detection
1: Detection
1 1
F19.39 Input voltage selection
Unit : 380V input voltage
0: 380 - 460V
1: 260 - 460V
2: 200 - 460V
Ten: 220V input voltage selection
0: 200 - 240V
1: 140 - 240V
00 1
×
F19.44 LCD Backlight display time 0.0 - 999.9min 5.0min
0.1
min
F20: Fault Protection Parameter
F20.00
Selection for overload
prediction police check out
00000: Enbale overload protection
10000: Disbale overload protection
00000 1
F20.02
Overload pre-alarm
detection time
0.0 - 60.0s 5.0s 0.1s
F20.10
Output phase loss
detection reference
0 - 50% 20% 1%
×
F20.11
Output phase loss
detection time
0.00 - 20.00s 3.00s 0.01s
×
F20.18 Auto reset times 0 - 100 0 1
×
F20.19 Auto reset interval 2.0 - 20.0s / times
5.0s /
times
0.1s /
times
×
F20.21
Type of third latest (the
last) fault
-Lu-: DC bus undervoltage
E0001: Acc overcurrent
E0002: Dec overcurrent
0 1 *