Shenzhen Hpmont Technology Co., Ltd. Chapter 10 Parameter
HD09 Series User Manual V1.1 -83-
Ref. Code
Function
Setting Range
Default
Unit
Attribute
Setting
E0003: Costant overcurrent
E0004: Acc overvoltage
E0005: Dec overvoltage
E0006: Constant overvoltage
E0007: Stall overvoltage
E0008: Fault of powermodule
E0009: Heatsink overheat
E0011: CPU fault
E0012: Parameters auto-tuning fault
E0013: Contactor is not actuated
E0014: Fault of current detection circuit
E0016: Fault of output phase
E0017: Inverter overload
E0019: Motor overload
E0021: Access fault of control board
EEPROM
E0024: Fault of external equipment
E0028: SCI communication time-out
E0029: SCI communication error
F20.22
Setting frequency at the
last fault
0.0 - 1000.0Hz 0.0Hz 0.1Hz *
F20.23
Running frequency at the
last fault
0.0 - 1000.0Hz 0.0Hz 0.1Hz *
F20.24 Bus voltage at the last fault 0 - 999V 0V 1V *
F20.25
Output voltage at the last
fault
0 - 999V 0V 1V *
F20.26
Output current at the last
fault
0.00 - 99.99A 0.00A 0.01A *
F20.29 Interval of third latest fault 0.0 - 6553.5h 0.0h 0.1h *
F20.30 Type of second latest fault 0 - 99 0 1 *
F20.31
Interval of second latest
fault
0.0 - 6553.5h 0.0h 0.1h *
F20.32 Type of first latest fault 0 - 99 0 1 *
F20.33 Interval of first latest fault 0.0 - 6553.5h 0.0h 0.1h *
F23: PWM Controlling Parameter
F23.00 Set the carrier frequency 1 - 16kHz 4kHz 1kHz
×