9 Troubleshooting
9.1 General
This chapter describes faults that may occur and how to deal with these faults. If the faults
cannot be dealt with, or if there are other faults, contact your nearest retailer. For contact
information, see the start of the manual.
Fault description Cause Instruction user
Fault code is shown in HMI.
One of the machine's alarm
systems has been activated.
For more information see
Warnings and Error
Messages.
The machine loses contact
with other units.
The CAN bus signal is
broken.
Check cable connections on
the connection panel.
9.2 The machine will not start
Error source Cause Instruction user
Electrical supply
Fault on supply, e.g. fuses,
earth fault breakers or
connecting cables
Check correct voltage on
incoming phase/phases.
Power supply
Power supply indication is
not lit
Check miniature circuit
breaker F1.
Mainboard Main circuit board is not lit
Check fuse F2, red LED.
Fuse
Standby LED on the control
panel Panel is not lit