HTC DURATIQ Troubleshooting
54 www.htc-floorsystems.com
D004753, 01.01
Symbol Warning Fault description Action
VOLTAGE LOW
Low input voltage to
machine.
Check voltage level
during operation.
Check cable area.
Check electrical supply.
9.5.2 Error Messages
Symbol Error Message Fault description Action
CANBUS ERROR Error on CAN bus.
Check cabling. Check
units connected to
HMI.
EMERGENCY STOP
ACTIVATED
Emergency stop
activated.
Reset emergency stop.
GENERIC INVERTOR
ERROR
Generic error converter.
Go to
www.htc-
floorsystem.com and
select support.
GENERIC........ ERROR
(error code)
Generic error converter.
HEATSINK
TEMPERATURE HIGH
Cooling flange for
frequency converter is
overheated.
Fans are not standard.
Recommended for
ambient temperatures
>30°C.
Let the frequency
converter cool down.
INVERTER OVERLOAD
The converter is
overloaded.
Let the machine cool
down.
MOTOR NOT
CONNECTED
Break in grinding
motor/grinding motor
cabling.
Check grinding motor
cabling. Check
measure grinding
motor.
MOTOR OVERHEAT
Grinding motor is
overheated.
Let the motor cool
down.
MOTOR OVERLOAD
Grinding motor becomes
overloaded. Overload
meter up to 100%.
Let the machine cool
down.
MOTOR SHORT
CIRCUIT
Grinding motor
short-circuited.
Check grinding motor
cabling. Insulation
measure grinding
motor.

Related product manuals