5
LP-04 REV. 4.15.14
COLD WEATHER HANDLING If the heater has been stored in a very cold location (BELOW 0
o
F) before installation, handle with care
until the plastic components come to room temperature.
A. SPECIFICATIONS AND PERFORMANCE RATINGS
Figure 1 LP-04-C
MODEL
GAL.
CAP.
WATTAGE
VOLTAGE
A
B
D
INLET /
OUTLET
APPROX. SHIPPING
WEIGHT (LBS.)
EV-6
6
1500*
120*
4 ½”
9 ¼”
14 ¼”
½”
19
EV-12
12
1500*
120*
3 ½”
12 ¼”
16 ¼”
½”
26
EV-20
20
1500*
120*
4 ¾”
22”
19 ¼”
¾”
41
EV-30
30
4500
240
4 ¾”
34 ¼”
19 ¼”
¾”
55
EV-30LB
30
4500
240
4 ¾”
21 ¾”
23 ¼”
¾”
65
EV-45LB
45
4500
240
4 ¾”
34 ¾”
23 ¼”
¾”
86
EV-50
50
4500
240
4 ¾”
56”
19 ¼”
1”
90
EV-80
80
4500
240
5 ½”
64 ¼”
23 ¼”
1”
132
Table 1 Specifications and Dimensions - *Available with Special Order 240V/4500W Element Part # E1001
B. LOCATING THE WATER HEATER
Locate the water heater where any leakage from the relief valve, related piping, tank, or connections will not result in damage to
surrounding areas or lower floors of the building. The water heater should be located near a floor drain, or installed in a drain pan. HTP
WILL NOT be held liable for leakage damages.