EasyManua.ls Logo

HTP Hydra Smart RT-150 - User Manual

HTP Hydra Smart RT-150
73 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Hydra Smart
Tankless Water Heaters
Installation
Start-Up
Maintenance
Parts
Warranty
RT-150 / 199* Models
* “LP Denotes Propane Gas
This manual must only be used by a qualied installer / service technician. Read all instructions in this manual before installing.
Perform steps in the given order. Failure to do so could result in substantial property damage, severe personal injury, or death.
The manufacturer reserves the right to make product changes or updates without notice and will not be held liable for
typographical errors in literature.
NOTE TO CONSUMER: PLEASE KEEP ALL INSTRUCTIONS FOR FUTURE REFERENCE.
272 Duchaine Blvd. New Bedford, MA 02745 www.htproducts.com
lp-505 Rev. 000 Rel. 015 Date 1.7.20
The surfaces of these products contacted by potable (consumable) water contain less than 0.25% lead by weight as required
by the Safe Drinking Water Act, Section 1417.
Improper installation, adjustment, alteration, service, or maintenance could void product warranty and cause property
damage, severe personal injury, or death.
California Proposition 65 Warning: This product contains chemicals known to the State of California to cause cancer, birth
defects, or other reproductive harm.

Table of Contents

Other manuals for HTP Hydra Smart RT-150

Questions and Answers

  • C
    Charles EllisNov 24, 2025
    What to do if ignition has failed multiple times on my HTP Hydra Smart RT-150 Water Heater?
    • M
      mark43Nov 24, 2025
      If the ignition has failed 10 times on your HTP Water Heater, try the following: First, press the Power button to clear the Error Code (it will also automatically reset after one hour, up to three times). If the error happens again: 1. Monitor the gas pressure to the water heater while in operation, ensuring it's between 3.5 and 14” WC. 2. Check the gas valve wire and flame detection sensor, ensuring connections are secure; normal operating settings for the flame detection sensor are more than 2.5DC before ignition, less than 2.5DC after ignition. 3. Check the igniter transformer for proper connection. 4. Clean the spark igniter with steel wool to remove oxides and ensure proper separation (3-4 mm). Replace the spark igniter if damaged. 5. Assure that the flame is stable when lit. I...
  • Y
    yrayAug 23, 2025
    How to fix HTP Hydra Smart RT-150 Water Heater if the flame has extinguished multiple times?
    • O
      opayneAug 23, 2025
      If the flame has extinguished 8 times on your HTP Water Heater, try the following: First, press the Power button to clear the Error Code (it will also automatically reset after one hour, up to three times). If the error happens again: * Monitor the gas pressure to the water heater while in operation, ensuring it's between 3.5 and 14” WC. * Check the gas valve wire and flame detection sensor, ensuring connections are secure; normal operating settings for the flame detection sensor are more than 2.5DC before ignition, less than 2.5DC after ignition. * Check vent terminations to ensure there are no blockages. * Assure that the flame is stable when lit. If the problem persists, replace the main control.
  • T
    tammydeleonAug 27, 2025
    Why is my HTP Hydra Smart RT-150 Water Heater overheating?
    • N
      Norman GarciaAug 27, 2025
      If your HTP Water Heater displays an error due to the operating temperature sensor or DHW sensor detecting water temperature greater than 199oF (93oC), the error code will disappear when the DHW temperature decreases. If the error happens again: * Check if the dip switch High Fire setting is ON (switches 6 and 7 should be OFF for normal operation). * Check if the DHW inlet pipe is blocked, ensuring enough water flows to the water heater. * Check the DHW sensor at the DHW outlet and the Operating Temperature sensor at the heat exchanger; if resistance is zero, replace the sensor. If the problem persists, replace the main control.
  • D
    Dalton RogersAug 27, 2025
    How to troubleshoot high exhaust temperature on HTP Water Heater?
    • D
      Dwayne RamirezAug 28, 2025
      If the exhaust NTC on your HTP Water Heater detects a vent temperature greater than 149oF (65oC) (or 190oF [87.8oC] when the High Temp set point is selected), the Error Code will disappear when the condition is remedied. If the error happens again: 1. Check if the dip switch High Fire setting is ON (switches 6 and 7 should be OFF for normal operation). 2. Check the exhaust temperature sensor, ensuring connections are secure. 3. Check the sensor resistance; if resistance is zero, replace the sensor. 4. Check the exhaust vent for blockage. If the problem persists, replace the control or the heat exchanger.
  • M
    Mary MorganAug 29, 2025
    What does 'Fan Speed Feedback Signal Abnormal' mean on my HTP Hydra Smart RT-150?
    • R
      Robert NunezAug 29, 2025
      If your HTP Water Heater displays a 'Fan Speed Feedback Signal Abnormal' error, the Error Code will disappear when the condition is remedied. If the error happens again: * Check the connections to the fan, ensuring all are secure. * If the fan does not rotate during the ignition sequence, check for 120V power at the fan connection. If 120V power is present at the control, replace the fan. If the blower does not have 120V power, check power at the control. If 120V power is not present at the control, replace the control. If the problem persists, replace the main control.
  • V
    Vanessa JacksonSep 18, 2025
    What does Exhaust Sensor Open or Short mean on HTP Hydra Smart RT-150 Water Heater?
    • C
      carlapierceSep 19, 2025
      If your HTP Water Heater displays an 'Exhaust Sensor Open or Short' error, this Error Code will disappear when the exhaust temperature decreases. If the error happens again: * Check the exhaust temperature sensor, ensuring connections are secure. * Check sensor resistance; if resistance is zero, replace the sensor. * Check the exhaust vent for blockage. If the problem persists, replace the main control.
  • C
    Charles HodgesSep 16, 2025
    What does Water Outlet Sensor Open or Short mean on HTP Hydra Smart RT-150?
    • M
      Melissa CarterSep 16, 2025
      If your HTP Water Heater displays a 'Water Outlet Sensor Open or Short' error, this Error Code will disappear when the outlet water temperature decreases. If the error happens again: * Check the DHW outlet temperature sensor, ensuring connections are secure. * Check sensor resistance; if resistance is zero, replace the sensor. If the problem persists, replace the main control.
  • D
    Daniel JonesSep 18, 2025
    How to troubleshoot H/X Temperature Sensor error on HTP Water Heater?
    • B
      Brett RodriguezSep 18, 2025
      If your HTP Water Heater displays an 'H/X Temperature Sensor Open or Short' error, this Error Code will disappear when the outlet water temperature decreases. If the error happens again: * Check the operating temperature sensor, ensuring connections are secure. * Check sensor resistance; if resistance is zero, replace the sensor. If the problem persists, replace the main control.
  • R
    Rachael RowlandSep 8, 2025
    How do I fix a Flue APS fault on my HTP Hydra Smart RT-150?
    • D
      dayjohnSep 8, 2025
      If your HTP Water Heater displays a 'Flue APS - Closed is Normal, Open is Fault (Condensate Drain Trap)' error, press the Power button to clear the Error Code. Then: * Check FLUE APS and main controller connections, ensuring all are secure. * Check FLUE APS resistance; if resistance is zero, replace the switch. * Check the FLUE APS hose, ensuring it is connected and in good condition. * Check the exhaust vent for blockages. If the problem persists, replace the main control.
  • C
    Charles ThompsonSep 5, 2025
    What to do if my HTP Water Heater shows a 'Poor Communication' error?
    • B
      Benjamin RichSep 6, 2025
      If your HTP Water Heater displays a 'Poor Communication' error, the Error Code will disappear when the condition is remedied. If the error happens again: * Check connections from the main control to the display panel. If the problem persists, replace the display and/or the main control.

HTP Hydra Smart RT-150 Specifications

General IconGeneral
BrandHTP
ModelHydra Smart RT-150
CategoryWater Heater
LanguageEnglish