What to do if water pressure is too high in my HTP SSC-50 Water Heater?
- SSusan RaymondAug 22, 2025
If the water pressure is too high, install a pressure reducing valve.
What to do if water pressure is too high in my HTP SSC-50 Water Heater?
If the water pressure is too high, install a pressure reducing valve.
What to do if circulator is not operating in my HTP SSC-50 Water Heater?
If the circulator is not operating, check or replace it.
How to fix air trap in loop of my HTP SSC-50 Water Heater?
To fix an air trap in the loop, purge the air.
What to do if water expands when heated in my HTP SSC-50?
If water expands when heated, install an expansion tank.
What to do if zone valve fails in my HTP SSC-50 Water Heater?
If the zone valve fails, replace the valve.
What to do if tank control fails in my HTP Water Heater?
If the tank control fails, replace the control.
What to do if circulator fails in my HTP SSC-50?
If the circulator fails, replace the circulator.
How to solve zone valve not opening in my HTP SSC-50 Water Heater?
To solve the issue of the zone valve not opening, open it manually to replace it.
Why is my HTP SSC-50 not producing enough hot water?
There could be several reasons why your HTP Water Heater isn't providing enough hot water. These include a zone valve restriction (replace zone valve with a 1” full bore), a reversed circulator arrow (reverse the circulator), or a boiler temperature that is too low (raise the boiler temperature). Other potential causes are: the boiler or tank being too small (check sizing chart), a demand flow rate that is too high (check sizing chart), an air trap in the loop (purge to remove air), the heat and tank coming on together (recheck wiring or coincidence), not enough space heat (boiler sized too small - consult chart), or a slow recovery (circulator head capacity too low).
What to do if my HTP SSC-50 has no hot water?
If your HTP Water Heater isn't producing any hot water, several factors could be the cause. These include a zone valve not opening (check or replace), a circulator not operating (check or replace), a tank control set too low (raise tank temperature), a boiler control set too low (raise boiler temperature), incorrect wiring (recheck wiring), a tank control failure (replace control), or an air trap in the loop (purge air).
Brand | HTP |
---|---|
Model | SSC-50 |
Category | Water Heater |
Language | English |
Safety precautions for maintenance and servicing the system.
Safe temperature settings to prevent scalding and related risks.
Installation and function of the T&P relief valve.
Risks and prevention of scalding from hot water.
Details on the surface-mounted control unit and its settings.
Guidelines for safe and compliant electrical wiring procedures.
Solutions for common operational problems and error conditions.