SUN2000-(2KTL-6KTL)-L1
User Manual
Issue 10
Date 2023-02-13
HUAWEI TECHNOLOGIES CO., LTD.

Table of Contents

Other manuals for Huawei 01075345

Questions and Answers

  • M
    Michael WatersAug 30, 2025
    What to do if Huawei 01075345 shows AFCI Check Failure?
    • C
      Chad CunninghamAug 30, 2025
      If your Huawei Inverter displays an AFCI Check Failure, turn off the AC output switch and DC input switch, and then turn them on after 5 minutes.
  • C
    Cameron NicholsonSep 7, 2025
    What causes a DC Arc Fault in a Huawei 01075345?
    • H
      hammondjamesSep 7, 2025
      A DC Arc Fault in your Huawei Inverter can be caused by arcing or poor contact in the PV string power cables. Check whether the string cables arc or are in poor contact.
  • R
    Rhonda JonesAug 29, 2025
    What to do if my Huawei 01075345 Inverter shows Low Insulation Resistance?
    • C
      Christopher MendozaAug 29, 2025
      If your Huawei Inverter shows a Low Insulation Resistance error, it indicates a short circuit between the PV array and the ground, or that the ambient air of the PV array is damp, causing poor insulation. First, check the output impedance of the PV array to ground. If there is a short circuit or lack of insulation, rectify it. Second, check that the PE cable of the SUN2000 is correctly connected. Third, if the impedance is lower than the specified protection threshold in rainy and cloudy days, set Insulation resistance protection using the mobile app, SmartLogger, or NMS.
  • U
    uhartSep 18, 2025
    What does Grid Underfrequency mean for Huawei 01075345 Inverter?
    • S
      stacey69Sep 18, 2025
      If your Huawei Inverter shows a 'Grid Underfrequency' error, the power grid frequency is too low. Here's how to address it: 1. If the alarm occurs occasionally, the power grid may be temporarily abnormal. The SUN2000 will automatically recover when the grid returns to normal. 2. If it happens frequently, check if the grid frequency is within the allowed range. If not, contact your local power operator. If it is, modify the grid underfrequency protection threshold via the mobile app, SmartLogger, or NMS with the power operator's consent.
  • A
    anne08Sep 8, 2025
    How to fix String Reversed error on Huawei 01075345 Inverter?
    • I
      Isaac MartinSep 8, 2025
      If your Huawei SUN2000 Inverter shows a String Reversed error, it means the PV string is reversely connected. To resolve this, check if the PV string is reversely connected to the SUN2000. If it is, wait until the PV string current decreases below 0.5 A, set the DC switch to OFF, and adjust the PV string polarity.
  • M
    Mr. Joe ScottSep 12, 2025
    What to do if my Huawei 01075345 Inverter has a Device Fault?
    • A
      ahowellSep 12, 2025
      If your Huawei SUN2000 Inverter has a Device Fault, turn off the AC output switch and DC input switch, and then turn them on after 5 minutes.
  • C
    cevansSep 16, 2025
    How to cool down my Huawei Inverter?
    • W
      wellsleahSep 16, 2025
      If your Huawei Inverter is overheating, it's likely installed in a poorly ventilated area, the ambient temperature is too high, or the device isn't working correctly. Check the ventilation and ambient temperature around the installation location.
  • L
    Larry ArmstrongSep 23, 2025
    How to fix Upgrade Failed on Huawei Inverter?
    • M
      Melissa VincentSep 23, 2025
      If the Huawei Inverter displays 'Upgrade Failed or Version Mismatch', it means the upgrade did not complete normally. Try performing the upgrade again. If it fails multiple times, contact your dealer or Huawei technical support.
  • A
    alanalexanderAug 26, 2025
    What to do if my Huawei 01075345 Inverter showing Overtemperature?
    • R
      ray27Aug 26, 2025
      If your Huawei Inverter is showing an Overtemperature warning, it indicates that the unit is installed in a location with poor ventilation, the ambient temperature is too high, or the SUN2000 is not working properly. You should check the ventilation and ambient temperature of the SUN2000 installation position. If the ventilation is poor or the ambient temperature exceeds the upper threshold, improve the ventilation and heat dissipation.
  • J
    Jennifer MendezAug 25, 2025
    What to do if Huawei 01075345 Inverter displays DC Arc Fault?
    • L
      Lauren JohnsonAug 26, 2025
      If your Huawei Inverter displays a DC Arc Fault, it means the PV string power cables are arcing or have poor contact. You should check whether the string cables arc or are in poor contact.