SUN2000-(2KTL-6KTL)-L1
User Manual
Issue 10
Date 2023-02-13
HUAWEI TECHNOLOGIES CO., LTD.

Table of Contents

Other manuals for Huawei 01075345

Questions and Answers

  • M
    Michael WatersAug 30, 2025
    What to do if Huawei 01075345 shows AFCI Check Failure?
    • C
      Chad CunninghamAug 30, 2025
      If your Huawei Inverter displays an AFCI Check Failure, turn off the AC output switch and DC input switch, and then turn them on after 5 minutes.
  • J
    Jessica SimsAug 29, 2025
    What does Active Islanding mean on my Huawei 01075345?
    • I
      Isaiah RodriguezAug 29, 2025
      If your Huawei Inverter is showing Active Islanding, it means that the SUN2000 has proactively detected islanding when the power grid experiences an AC power outage. Check that the grid connection voltage of the SUN2000 is normal.
  • R
    Rhonda JonesAug 29, 2025
    What to do if my Huawei 01075345 Inverter shows Low Insulation Resistance?
    • C
      Christopher MendozaAug 29, 2025
      If your Huawei Inverter shows a Low Insulation Resistance error, it indicates a short circuit between the PV array and the ground, or that the ambient air of the PV array is damp, causing poor insulation. First, check the output impedance of the PV array to ground. If there is a short circuit or lack of insulation, rectify it. Second, check that the PE cable of the SUN2000 is correctly connected. Third, if the impedance is lower than the specified protection threshold in rainy and cloudy days, set Insulation resistance protection using the mobile app, SmartLogger, or NMS.
  • J
    jmartinezSep 12, 2025
    What does Abnormal PV Module Configuration mean on a Huawei 01075345 Inverter?
    • W
      William ShermanSep 12, 2025
      If your Huawei Inverter shows an Abnormal PV Module Configuration error, it means that the PV module configuration does not meet requirements, or the PV module output is reversely connected or short-circuited. Check whether the total number of PV modules, number of PV modules in a string, and number of PV strings meet requirements and whether the PV module output is reversely connected.
  • C
    cevansSep 16, 2025
    How to cool down my Huawei Inverter?
    • W
      wellsleahSep 16, 2025
      If your Huawei Inverter is overheating, it's likely installed in a poorly ventilated area, the ambient temperature is too high, or the device isn't working correctly. Check the ventilation and ambient temperature around the installation location.
  • M
    Maria GarciaSep 23, 2025
    Why is Huawei Inverter showing Off-grid output overload?
    • G
      Gregory BatesSep 23, 2025
      If your Huawei Inverter shows an 'Off-grid output overload' message, the output is either overloaded or short-circuited. Check whether the device output is short-circuited and whether the device load configuration exceeds the rated value.
  • C
    Carolyn PerryAug 27, 2025
    What to do if Huawei Inverter displays Grid Undervoltage?
    • M
      Michele MoralesAug 27, 2025
      If your Huawei Inverter displays a Grid Undervoltage alarm: * If the alarm occurs occasionally, the power grid may be temporarily abnormal. The SUN2000 will automatically recover once the power grid returns to normal. * If the alarm occurs frequently, check whether the power grid voltage is within the allowed range. If it is not, contact the local power operator. If it is, modify the grid undervoltage protection threshold via the mobile app, SmartLogger, or network management system (NMS) with the consent of the local power operator. * If the fault persists for a long time, check the connection between the AC switch and the output power cable.
  • W
    Wayne MartinAug 27, 2025
    What to do if Huawei Inverter displays String Reversed?
    • Z
      zmaldonadoAug 27, 2025
      If your Huawei Inverter displays a String Reversed error, it means the PV string is reversely connected. Check whether the PV string is reversely connected to the SUN2000. If it is, wait until the PV string current decreases below 0.5 A, set the DC switch to OFF, and adjust the PV string polarity.
  • A
    alanalexanderAug 26, 2025
    What to do if my Huawei 01075345 Inverter showing Overtemperature?
    • R
      ray27Aug 26, 2025
      If your Huawei Inverter is showing an Overtemperature warning, it indicates that the unit is installed in a location with poor ventilation, the ambient temperature is too high, or the SUN2000 is not working properly. You should check the ventilation and ambient temperature of the SUN2000 installation position. If the ventilation is poor or the ambient temperature exceeds the upper threshold, improve the ventilation and heat dissipation.
  • J
    Jennifer MendezAug 25, 2025
    What to do if Huawei 01075345 Inverter displays DC Arc Fault?
    • L
      Lauren JohnsonAug 26, 2025
      If your Huawei Inverter displays a DC Arc Fault, it means the PV string power cables are arcing or have poor contact. You should check whether the string cables arc or are in poor contact.

Huawei 01075345 Specifications