Prerequisites
The network deployment is complete.
The installation of the eA380 is complete.
The eA380 starts appropriately based on default parameters after power-on.
Procedure
When the LTE CPE fails to access the Internet, run the Ping function to quickly check
the network connection status.
3. Start the IE browser, enter https://192.168.1.1 in the address bar, and press Enter. Log
in to the Web management page, and enter User name and Password.
Use Internet Explorer 9 (IE9) or a later version.
4. Choose Settings > TR-069 Management> Diagnosis to open the Diagnosis page.
5. Set Diagnosis Method to Ping.
6. Enter the domain name in the Destination IP address/domain name box.
7. Click Apply.
8. Wait until the operation is performed. The command output is displayed in the Result
box.
Timeout indicates the timeout period of each reply, and ranges from 1 to 10 seconds.
When the LTE CPE does not run properly, the System Check can be used to
preliminarily identify the problem.
Start the IE browser, enter https://192.168.1.1 in the address bar, and press Enter. Then
enter the correct password and click Log In.
Use Internet Explorer 9 (IE9) or a later version.
9. Choose Settings > TR-069 Management> Diagnosis to open the Diagnosis page.
10. Set Diagnosis Method to System Check.
11. Click Check.
12. Wait until the system check is performed. Click Export to export the detailed
information to the computer. If necessary, send the detailed information to maintenance
personnel.
----End