Conguratio
n
Maximum
Front Drives
Maximum
Rear Drives
Maximum
Built-in
Drives
Drive
Management
Mode
a: The front drives and I/O module 3 support only 2.5-inch drives.
NOTE
Other front drive congurations and I/O modules support 2.5-inch and 3.5-inch drives.
b: If an SP460C-M (Broadcom SAS3516) RAID controller card is used, I/O
module 2 cannot hold drives.
c: I/O module 3 supports only SAS/SATA drives when the server is congured
with an SR760-M (Broadcom SAS3416), SR760IT-M (Broadcom SAS3416), or
SP460C-M (Broadcom SAS3516) RAID controller card.
d: Built-in drives are supported only when the server is
congured with an
SR760-M (Broadcom SAS3416), SR760IT-M (Broadcom SAS3416), or SP460C-
M (Broadcom SAS3516) RAID controller card.
e: Only the SR760-M (Broadcom SAS3416) or SR760IT-M (Broadcom
SAS3416) RAID controller card can be used to manage common drives.
f: Only PCH can be used for drive management. The PCH supports only SATA
drives.
g: A RAID controller card or PCH can be used to manage common drives
(slots 0 to 7). The PCH supports only SATA drives.
h: Every eight front drives require a RAID controller card. A maximum of
three RAID controller cards are supported.
Contact your local Huawei sales representative or use the Intelligent
Computing Compatibility Checker to determine the components to be
used.
5.5.2 Drive Numbering
8 x 2.5" drive conguration
Figure 5-24 Drive numbering
12 x 3.5" drive EXP conguration 1
Huawei FusionServer Pro 2288H V5 Server
Technical White Paper 5 Hardware Description
Issue 12 (2020-04-20) Copyright © Huawei Technologies Co., Ltd. 38