When a single fan is faulty:
The maximum operating temperature is 5°C (41°F) lower than the rated value.
System performance will be aected if GPU cards are congured.
If P4 GPU cards are congured:
The server supports the maximum operating temperature of 35°C (95°F) when
holding three or less GPU cards.
The server supports the maximum operating temperature of 30°C (86°F) when
holding four or more GPU cards.
If V100 GPU cards are congured:
Only the 8 x 2.5" drive conguration is supported.
The maximum operating temperature is 30°C (86°F).
A.3 Nameplate
Certied Model Usage Restrictions
H22H-05 Global
H22H-05-I10 India only
H22H-05-I12 India only
A.4 RAS Features
The server supports a variety of Reliability, Availability, and Serviceability (RAS)
features. You can
congure these features for better RAS.
For details about how to congure RAS features, see Huawei Server Purley
Platform BIOS Parameter Reference.
Table A-3 RAS features
Module
Feature Description
CPU Corrected Machine Check
Interrupt
Corrects error-triggered interruption.
DIMM Failed DIMM Isolation Identies a faulty DIMM and isolates it
from others before it is replaced.
Memory Thermal
Throttling
Automatically adjusts DIMM
temperatures to avoid damage due to
overheating.
Rank Sparing Allocates some memory ranks as
backup ranks to prevent the system
from crashing due to uncorrectable
errors.