Table 5-9 Description of SAS/SATA drive indicators
Activity Indicator
(Green)
Fault Indicator
(Yellow)
Description
Steady on O The drive is in position.
Blinking at 4 Hz O Data is being read or written normally,
or data on the primary drive is being
rebuilt.
Steady on Blinking at 1 Hz The drive is being located.
Blinking at 1 Hz Blinking at 1 Hz The data on the secondary drive is
being rebuilt.
O Steady on A member drive in the RAID array is
removed.
Steady on Steady on The drive is faulty.
NVMe Drive Indicators
Figure 5-34 NVMe drive indicators
● If the VMD function is enabled and the latest VMD driver is installed, the
NVMe drives support surprise hot swap.
Table 5-10 Description of NVMe drive indicators (VMD enabled)
Activity
Indicator
(Green)
Fault Indicator
(Yellow)
Description
O O The NVMe drive cannot be detected.
Steady on O The NVMe drive is working properly.
Blinking at 2 Hz O Data is being read from or written
to the NVMe SSD.
O Blinking at 2 Hz The NVMe drive is being located.
Huawei FusionServer Pro 2288H V5 Server
Technical White Paper 5 Hardware Description
Issue 12 (2020-04-20) Copyright © Huawei Technologies Co., Ltd. 43