Huawei SAP HANA Appliance Single Node Installation
Guide (RH2288H V3+Broadwell+SLES11 SP4 For B1)
3 Configuring RAID Parameters
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
18
Figure 3-10 VD Mgmt page
Step 6 Create VD1:in the main administration page press the "F2" key to enter the selection menu, as
show Figure 3-11, select "Creat Virtual Drive" item;
Figure 3-11 Create virtual Drive
Step 7 When you select Create virtual Drive item, enter VD1 the RAID configuration parameters
page,this example, there are 18 disks configured as RAID50; "PD per Span "parameter should
be set to "9"; select the 18 disks, select "Advanced" for set advanced configuration parameters,
as show in Figure 3-12;